Installation in Unattended Mode 104
Example of the WAN-Miniport section
[WAN]
IgnoreCallbackNumber=0
NoAnswerTimeout=14
Logging=1
Protocol=0
ShortholdMode=1
ShortholdTime=100
CallbackPrefix=0
AuthProtocol=0
SecurityLevel=2
UserNameDelimiter=;
AuthTimeout=10
NumberChecking=0
NumberCheckingFile=
IgnoreCallbackNumber=0
ForceAnalogBcOnCallback=0
Port driver section
The Port driver can be installed with default parameters which means that no parameters
are defined in the ‘MODEMS’ section. However, if you need to change the default settings,
you can modify the following parameters:
Logging
Logging specifies which protocol and status messages are logged. Possibled settings are:
• 0: for error traces only
• 1: for standard tracing
• 2: for tracing of error messages, incoming and outgoing connection plus tracing of data
traffic of the B-channels or channelized T1 channels (size of data blocks, type of data
packets of the PPP connection, etc.)
• 3: for a full trace
The default is 1.
FirstPort
FirstPort (Assigning the first port) specifies to which serial ports the ISDN or channelized
T1 ports are assigned. During installation of Diva Server for Windows NT the ISDN or
channelized T1 ports are automatically assigned to the installed serial ports starting from
the first installed serial port counting consecutively upwards. If you want to assign other
serial ports to the Port driver, select a new port, e.g. COM 9, as first port. Allowed values
are 5 to 100.
The default is ‘5’.