G&R
Transport disconnect
‘Transport disconnect received’ errors after a connection attempt typically
mean that you have a physical problem with the link or a network configuration
problem. Look up the error code displayed in the XTI/OSI documentation. If
you are using the Bull OSI-stack on an AIX platform use the pmaderror
command to get the error code explained. Check with trace tools on the UNIX
side if any packets leave the UNIX system. The problem may possibly be on
the other side if transport does not manage to establish connection with the
session layer there. In this case some of the OSI stacks will deliver the X25 or
DSA reason code, in which case see the section entitled Error codes.
Session refused
Session refused or session aborted errors after a connection attempt typically
mean that you have Front-end or mainframe configuration errors, or a mismatch
between the Host Links and Front-end or mainframe configuration.
Look up the error code displayed in the OSI/DSA network system messages
and return codes manual, see the section entitled Error codes or use the
Gerror utility, see section entitled DSA test utilities on page 109.
Parameters for DSA/DIWS handler
The following parameters apply to this handler (defaults in uppercase):
Parameter Description
-LI DIWS
Start gl_dsa in DIWS protocol mode
-LI DSA
Start gl_dsa in DSA protocol mode
-LI DIWS:GATEWAY
Start gl_dsa in DIWS mode through Ggate running
on GATEWAY
-LI DSA:GATEWAY
Start gl_dsa in DSA mode through Ggate running
on GATEWAY
-AM SNM
Application mode GCOS6 SNM
GEN
Application mode general
AST
Application mode Datanet AST
Gline Line Handlers and Configuration