Seitenansicht 140
SDLC Status 141
Trace entry size (bytes)
This configures Trace to examine only the first
bytes of each frame or packet traced. If you have a Trace Entry Size of 512
bytes, only the first 512 bytes of each frame or packet is loaded into the trace
buffer.
Addr
The control unit (CU) hexadecimal address (up to FF) of the SDLC link
connection.
Type
The kind of station role the PC running your Eicon Networks software
is performing.
Protocol State
The current status of the SDLC protocol.
Value Description
Primary The PC running your Eicon Networks software is the primary (master)
multi-drop station.
Secondary The PC running your Eicon Networks software is a secondary (slave)
multi-drop station.
Value Description
Closed Protocol not activated.
Closing Terminating SDLC protocol.
Opening Activating SDLC protocol.
Opened SDLC active (Data mode).
Resetting SDLC line is resetting (Sent or received a SNRM).
Wait Reset Waiting for a remote to reset the SDLC line.
Wait Open When passive or DCE, wait for remote to activate the line using
SNRM.