DIALER Status 113
Global Status Fields
Card Number
Number of the Eiconcard being monitored.
Port Number
Number of the Eiconcard Port being monitored.
Dialer type
Type of interface connecting the gateway PC to local or remote
host computers.
State
Current state of the dialer.
Possible states for the Direct Dialer are:
Possible states for the AT Dialer are:
Value Description
Direct Direct dialer.
Asynchronous AT d i a l e r.
V.25bis Sychronous dialer
B-channel ISDN dialer
SIG.+X.25 ISDN dialer
Value Description
Closed Dialer not activated.
Opening Link is being set up.
Answering Accepting call from remote.
Delaying Waiting for a timer to expire.
Opened Physical link is established.
Closing Disconnecting the physical link.
Value Description
On hook Dialer is on hook.
Dialing Dialing a number.
Answering Accepting call from remote.
Ringing Incoming call present.
Retrying Awaiting new call attempt.
Off hook The physical link is established. Connection established.
HangingUp Disconnecting from DCE.