TTY Call filter directory
The "CallFilter" management interface directory allows for configuration of the call filters. The call filter allows for
processing of the calls with a specific Calling Party Number with a preconfigured protocol, instead of using the
protocol auto-detection procedure. This can be necessary for callers with non-standard behavior, that does not
allow reliable detection of the bearer protocol.
CallFilter directory
Name Type Attribut
e
Description
TotalFilters MI_UINT R Total amount of available call filters
ActiveFilters MI_UINT R Total amount of used filters
AvailableProtocols MI_UINT R Comma-separated list of the protocols that can be used in
call filters
FXX-YY MI_DIR R Directory that contains 50 (F1...F50) call filters
Reset MI_EXECUTE R Used to clear and to de-activate the filters
Every call filter consists of two entries: Calling Party Number and protocol to be used. The numbers are
compared from behind, i.e., 123 with math 123, 77123, 721999123, ... .
Call Filter entry
Name Type Attribute Description
Nr MI_UINT R Filter number
Number MI_ASCIIZ W Calling Party Number
Protocol MI_ASCIIZ W Protocol name
Reset MI_EXECUTE R Used to clear and to de-activate current filter