Eicon Networks ISDN NT1 Installationsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
Eicon Network Termination (NT1) Installation Guide 5
Note: The table uses metric measurements. The equivalent imperial
measures are: 75 m (250 ft), 150 m (500 ft), 900 m (3000 ft).
Table 1. Determining Termination Settings
2 Set the Required Termination
You must set the NT1 and your ISDN devices to the termination
value indicated by Table 1.
Set the termination on your ISDN devices to the value specified
under “Termination—Other Devices.” The manuals which came
with your ISDN devices can tell you how to do this.
To set the termination on the NT1, you manipulate five small switches
on the rear of the unit, shown in Figure 1, to match the settings given
under the heading “NT1 Switch Settings” in Table 1.
Figure 1. Rear Panel
Devices Connected to the NT1 Termination NT1 Switch Settings
ISDN Devices NT1 ISDN
Devices
1 2 3 4 5
# Number Distance
1 1 up to 75 m 50
None on on on on on
2or100
100
off on off on on
3 75 to 900 m 100
100
off on off on off
4 2 up to 75 m 50
None on on on on on
5orNone 100
off off off off on
6 75 to 150 m None 100
off off off off off
Connect your ISDN
wall socket to this port
Connect the power
supply to this port
Select the termination setting
using these switches